نام تجاری: | GENY |
شماره مدل: | YC1893D |
مقدار تولیدی: | 1 عدد |
قیمت: | قابل مذاکره |
شرایط پرداخت: | L/C، T/T، D/P |
توانایی عرضه: | 30 عدد در ماه |
GENY meter test systems leverage state-of-the-art electronic metrology and a modular architecture, integrating precision reference standards with high-stability power amplifiers to meet the exacting demands of energy-meter manufacturers, power utilities, metrology laboratories, inspection authorities, and industrial test facilities.
The YC1893D meter test system is a full-automatic test system for testing and calibration of both single-phase and three-phase electric energy meters, which composes of:
The YC1893D meter test system is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:
Technical spec. |
|
Number of meter positions |
24 |
Accuracy |
0.05 / 0.02 |
Power Source |
YCS-103-1200 |
Standard Meter |
SZ03A-K6 / SZ03A-K8 / Radian RD-33 |
Scanning Head |
YCG-S Series |
Voltage |
|
Test voltage output(Phase-Neutral) |
3* (24V~288V)(or customized) |
Power of the voltage output |
Max. 3x500VA |
Resolution |
Better than 0.01% of full scale value of range |
Setting accuracy |
Better than 0.05% at the final range value |
Stability |
Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load |
Better than 0.01% |
Distortion factor |
Better than 0.3% for linear resistance load |
Harmonic |
2nd~21st free programmable |
Current |
|
Test current output |
3* (1mA - 100A) |
Power of the current output |
Max. 3x750VA |
Resolution |
Better than 0.01% of full scale value of range |
Setting accuracy |
Better than 0.05% at the final range value |
Stability |
Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load |
Better than 0.01% |
Distortion factor |
Better than 0.3% for linear resistance load |
Harmonic |
2nd~21st free programmable |
Phase angle |
|
Range |
0~360⁰ |
Resolution |
0.01⁰ |
Setting accuracy |
0.1⁰ |
Frequency |
|
Range |
45Hz~65Hz |
Resolution |
0.01Hz |
Error display |
|
Type of error display |
Red LED |
Resolution of error displays |
8 digitals |
Other |
|
Voltage supply |
3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature |
-10°C~+40°C |
Relative humidity |
35%~85% |